Shopping security
In summary, the EA-PSB 11000-30 3U is a programmable, bidirectional, two-quadrant DC power supply from EA Elektro-Automatik in the PSB 10000 3U series, rated at 0 – 1000 V, 0 – 30 A, and 0 – 10,000 W in a 3U 19-inch rack-mount enclosure. It operates simultaneously as a precision constant-voltage / constant-current / constant-power / constant-resistance source (with fast crossover between modes) and as a regenerative electronic load that returns absorbed energy to the AC mains at efficiencies up to 95.5%. The unit ships in the Standard wide-range 3U configuration, with EA factory product code 30000750.
The EA-PSB 11000-30 3U is used for high-power battery cycling, EV powertrain and on-board charger characterization, fuel-cell and electrolyzer test, photovoltaic-inverter simulation, and any application that requires a DC source and a regenerative DC sink in the same enclosure. Its primary commercial advantage is energy recovery: in load operation it returns up to 95.5% of absorbed energy to the AC grid, eliminating the resistive-bank heat load and the HVAC overhead that accompanies conventional electronic loads in continuous-cycle test bays.
Autoranging means the 10,000 W output stage delivers full rated power across a wide combination of voltage and current values, not just at one fixed V/I corner. Within the 1000 V envelope the unit can supply higher current at lower voltages and reduced current at higher voltages, all while holding the 10,000 W constant-power characteristic. The practical effect is that a single EA-PSB 11000-30 3U can replace several traditional supplies that each cover narrow V/I rectangles, simplifying test-bay configuration and reducing capital outlay.
Hard performance grounding: CV load regulation ≤0.05% FS, CC load regulation ≤0.1% FS, CV stability ≤0.02% FS across 8 hours after warm-up, CV/CC line regulation ≤0.01% FS across the 208 – 480 V ±10% input range. CV ripple is ≤200 mV rms (300 kHz BWL) and ≤1000 mV peak-to-peak (20 MHz BWL). Voltage display accuracy is ≤0.05% FS and current display accuracy is ≤0.1% FS, both supported by 16-bit ADCs and DACs. CV rise/fall (10–90%) ≤10 ms in source mode and CC rise/fall ≤2 ms in sink mode. Output capacitance is 197 μF and resistance range is 1.2 Ω – 2000 Ω.
The PSB 10000 series is engineered to EN 61010-1, IEC 61010-1, UL 61010-1, CSA C22.2 No 61010-1, and BS EN 61010-1 safety standards, with EMC tested to EN 55011 (Class B for Standard models, Class A for US208V models), CISPR 11, FCC 47 CFR Part 15B, and the EN 61326-1 immunity test suite (EN 61000-4-2 through 61000-4-6). Built-in test profiles cover the EN 50530 photovoltaic inverter standard, Sandia PV models, and the LV123 / LV124 / LV148 automotive power-quality procedures, aligning the unit directly with the compliance frameworks used by global automotive, energy-storage, and grid-interface OEMs.
| Item | Notes |
|---|---|
| EA-PSB 10000 3U mainframe | EA-PSB 11000-30 3U (Factory product code 30000750) |
| AC input mating connector | 3-phase AC terminal block kit for site wiring |
| DC terminal cover | Contact protection cover for rear copper-blade DC output |
| Share-Bus / Master-Slave shorting plug or cable kit | For standalone operation and bus termination |
| Quick-start printed guide | Setup, safety, and first-power-on instructions |
| EA Power Control software | Available from the manufacturer for sequencing, logging, battery simulation, PV simulation |
The bidirectional architecture of the PSB 10000 series replaces two instruments — a programmable DC supply and a DC electronic load — with one chassis. In source mode the unit behaves as a precision four-mode regulator (CV / CC / CP / CR) with fast mode crossover. In sink mode it behaves as a regenerative electronic load: instead of converting the DUT’s output power to heat in a resistor bank, the PSB inverts it back to the AC mains. For continuous-cycle test environments the operating-cost difference between resistive dissipation and grid feedback is the dominant financial argument for the series.
The EA-PSB 11000-30 3U variant is the Standard wide-range 3U configuration. AC input voltage and per-phase current behavior depend on the variant; the table below reflects this exact configuration.
| Parameter | Value |
|---|---|
| Voltage range | 0 – 1000 V |
| Current range | 0 – 30 A (source and sink) |
| Power range | 10,000 W rated (6,000 W derated on 208 V utility for Standard wide-range units) |
| Resistance range | 1.2 Ω – 2000 Ω |
| Ripple in CV (rms) | ≤200 mV (300 kHz bandwidth limit) |
| Ripple in CV (pp) | ≤1000 mV (20 MHz bandwidth limit) |
| Umin for Imax (sink) | 4 V |
| Output capacitance | 197 μF |
| Efficiency (sink/source, up to) | 95.5% (at 100% power, 100% output voltage) |
| Parameter | Value |
|---|---|
| Load regulation | CV ≤0.05% FS; CC ≤0.1% FS; CP ≤0.3% FS; CR ≤0.3% FS + 0.1% FS of current (0–100% load) |
| Line regulation | CV ≤0.01% FS; CC ≤0.01% FS (208–480 V AC ±10%) |
| Stability (8 h) | CV ≤0.02% FS; CC ≤0.02% FS (after 30 min warm-up) |
| Temperature coefficient | CV ≤30 ppm/°C; CC ≤50 ppm/°C (after 30 min warm-up) |
| Compensation (remote sense) | ≤5% UNominal |
| Display accuracy | Voltage ≤0.05% FS; Current ≤0.1% FS |
| Rise/Fall time (10–90% / 90–10%) | CV: ≤10 ms (source); CC: ≤2 ms (sink) |
| Parameter | Value |
|---|---|
| OVP / OCP / OPP | All adjustable 0 – 110% of UNominal / INominal / PNominal |
| Overtemperature (OT) | DC terminal shuts down on insufficient cooling |
| AC input to DC terminal | 3750 Vrms (1 min, creepage >8 mm) |
| AC input to case (PE) | 2500 Vrms |
| DC terminal to interfaces | 1000 V DC (≤360 V models); 1500 V DC (≥500 V models) |
| DC pole to PE | Negative ±1500 V DC; Positive +2000 V DC |
| Parameter | Value |
|---|---|
| Voltage / Phases | Wide-range: Range 1 = 208 V ±10% / Range 2 = 380 – 480 V ±10%, 3-phase AC |
| Frequency | 45 – 65 Hz |
| Power factor | ca. 0.99 (active PFC) |
| Leakage current | <5 mA |
| PMax | Range 1 (208 V): 7 kW (derated). Range 2 (380–480 V): 11 kW |
| Inrush current | ≈54 A per phase @ 400 V (cold start, first switch-on, 23°C, 10% tolerance) |
| Phase current | Range 1 (208 V): ≤29 A per phase; Range 2 (380–480 V): ≤27 A per phase |
| Overvoltage category | II |
| Interface | Notes |
|---|---|
| USB | Built-in, galvanically isolated, host port for USB-stick data logging and sequencing |
| Ethernet | Built-in, 100 MBit, galvanically isolated |
| Analog (15-pin D-Sub) | Switchable 0–10 V / 0–5 V signal range; U/I/P/R control, monitor outputs, alarms, CV/CC status |
| Master-Slave bus | Parallel up to 64 units of any power class in the 10000 series |
| Share-Bus | Galvanically isolated, balances load distribution between paralleled units |
| Optional plug-in | CAN, CANopen, RS232, Profibus, EtherCAT, Profinet (1–2 ports), Modbus TCP (1–2 ports), Ethernet (1–2 ports) |
| Command languages | SCPI, ModBus; LabVIEW and IVI drivers |
| Parameter | Value |
|---|---|
| Form factor | 3U 19-inch rack-mount; 483 × 132 × 668 mm (overall depth min. 785 mm / 31 in) |
| Weight | 25.4 kg (56 lb) (10 kW unit) |
| Cooling | Forced airflow front-to-rear (temperature-controlled fans) |
| Operating / Storage temperature | 0 – 50 °C operating (rated power up to ≈40 °C); −20 – 70 °C storage |
| Humidity / Altitude | ≤80% RH non-condensing; ≤2000 m (≤6,600 ft) |
| Pollution degree / IP / Appliance class | Pollution degree 2; IP20; Appliance class I |