Built for Aussie job sites, this All Controls 450VAC Motor Run Capacitor range (plastic case) is the dependable swap for tired single-phase fan and pump motors in HVAC and refrigeration. Choose the correct MFD (µF) and you’ll typically see steadier RPM, lower running amps, and fewer nuisance “it’s still noisy” call-backs.
A motor run capacitor stays in the circuit while the motor is running, creating the phase shift a PSC (permanent split capacitor) motor needs to run smoothly and efficiently. In practical terms, it helps condenser fans, blowers, and many pump motors hold torque under load—so the motor doesn’t overheat, stall, or sound rough when the weather turns nasty.
These caps are made for continuous operation in real plant-room conditions, not just clean workshop benches. The 450VAC rating gives you extra headroom over 370VAC replacements, which is handy on older sites or long cable runs where voltage can swing.
Run capacitors aren’t a “close enough” component—match the MFD on the motor’s original capacitor unless the OEM spec says otherwise. Use the table below to pick the exact value and mounting style you need, then double-check the variant name at checkout so the job stays clean.
| SKU | Variant Name |
|---|---|
| HYRCS4B-1 | RUN CAPACITOR PLASTIC 1 MFD FIXED 8M BOLT |
| HYRCS4B-2 | RUN CAPACITOR PLASTIC 2 MFD WITH DETACH BOLT |
| HYRCS4B-3 | RUN CAPACITOR PLASTIC 3 MFD FIXED 8M BOLT |
| HYRCS4B-4 | RUN CAPACITOR PLASTIC 4 MFD FIXED 8M BOLT |
| HYRCS4B-5 | RUN CAPACITOR PLASTIC 5 MFD FIXED 8M BOLT |
| HYRCS4B-6 | RUN CAPACITOR PLASTIC 6 MFD FIXED 8M BOLT |
| HYRCS4B-7 | RUN CAPACITOR PLASTIC 7 MFD FIXED 8M BOLT |
| HYRCS4B-8 | RUN CAPACITOR PLASTIC 8 MFD FIXED 8M BOLT |
| HYRCS4B-10 | RUN CAPACITOR PLASTIC 10 MFD FIXED 8M BOLT |
| HYRCS4B-12 | RUN CAPACITOR PLASTIC 12 MFD FIXED 8M BOLT |
| HYRCS4B-14 | RUN CAPACITOR PLASTIC 14 MFD FIXED 8M BOLT |
| HYRCS4B-15 | RUN CAPACITOR PLASTIC 15 MFD FIXED 8M BOLT |
| HYRCS4B-16 | RUN CAPACITOR PLASTIC 16 MFD FIXED 8M BOLT |
| HYRCS4B-20 | RUN CAPACITOR PLASTIC 20 MFD FIXED 8M BOLT |
| HYRCS4B-25 | RUN CAPACITOR PLASTIC 25 MFD FIXED 8M BOLT |
| HYRCS4B-30 | RUN CAPACITOR PLASTIC 30 MFD FIXED 8M BOLT |
| HYRCS4B-35 | RUN CAPACITOR PLASTIC 35 MFD FIXED 8M BOLT |
| HYRCS4B-40 | RUN CAPACITOR PLASTIC 40 MFD FIXED 8M BOLT |
| HYRCS4B-45 | RUN CAPACITOR PLASTIC 45 MFD FIXED 8M BOLT |
| HYRCS4B-50 | RUN CAPACITOR PLASTIC 50 MFD FIXED 8M BOLT |
| HYRCS4B-55 | RUN CAPACITOR PLASTIC 55 MFD FIXED 8M BOLT |
| HYRCS4B-60 | RUN CAPACITOR PLASTIC 60 MFD FIXED 8M BOLT |
| HYRCS4B-65 | RUN CAPACITOR PLASTIC 65 MFD FIXED 8M BOLT |
| HYRCS4B-70 | RUN CAPACITOR PLASTIC 70 MFD FIXED 8M BOLT |
| HYRCS4B-80 | RUN CAPACITOR PLASTIC 80 MFD FIXED 8M BOLT |
When a condenser fan is “hunting”, noisy, or pulling more amps than it should, the run cap is one of the fastest wins—especially in summer when head pressure climbs. Fit the correct MFD, lock the bolt down properly, and you’ll usually get smoother operation and cooler windings, which saves the customer (and you) from repeat visits.
Match the MFD/µF to the original capacitor (or OEM spec) and keep the voltage rating equal or higher than what came out—never lower. After install, do a quick capacitance test (and a current check) so you can confidently sign off the job knowing you’ve fixed the cause, not just the symptom.
These are for single-phase PSC motors used in condenser fans, indoor blowers, ventilation fans and many pump motors, plus some single-phase compressor circuits where a run capacitor is specified. This is not a start capacitor—if the motor needs extra starting torque, you’ll want a dedicated start capacitor or hard-start kit.
From humid Brisbane plant rooms to salty coastal installs around Newcastle and Sydney, capacitors cop vibration and heat day after day. A secure bolt mount and tidy terminations reduce failures, so the cap stays put and the motor stays stable—no worries.
You’ll receive one All Controls 450VAC motor run capacitor in the MFD value you select at checkout. Because this listing is variant-based, it’s worth double-checking the old capacitor label before ordering so the replacement is like-for-like.
Covered by HVAC Shop’s Shipping & Returns policy. If your part arrives damaged or incorrect, we’ll sort it promptly so you can get back on the tools.
Best practice is to match the manufacturer’s MFD rating because changing MFD can increase motor current and heat. If you’re unsure, test the motor current and confirm OEM data before deviating from the specified value.
P0 indicates no pressure interrupter, while P2 generally includes additional safety features depending on the capacitor design. Replace like-for-like unless the OEM specifies an upgrade, especially on critical motors.
Yes—using the same MFD with a higher voltage rating (450VAC replacing 370VAC) is commonly acceptable and can add margin in hot conditions. Never go lower than the OEM voltage rating.
Not always—PSC motors typically run on a run cap only, but some compressor and pump setups use a separate start component. If the motor struggles to kick or the circuit specifies it, add the correct start solution rather than guessing.